F5E-Therm electronic thermostatic in-wall mixer for separate power supply

F5E-Therm thermostatic mixer DN 15 as finished installation kit for in-wall installation in basic installation kit, for sanitary facilities. Opto-electronically controlled, for connection to hot water and cold water. Function block with integrated solenoid valve cartridge, thermostat and device for optional bypass solenoid valve cartridge, for program-controlled thermal disinfection. Thermostat with metal handle with adjustable and turn-proof temperature stop and option for manual thermal disinfection. Visible parts made of high-polished chromium-plated brass. Holding frame with profile seal, stainless steel cover plate 190 x 245 mm with covered screw fixing including sensor with control electronics, rosette, backflow preventer and strainers. Spout with laminar jet controller with integrated flow regulator 6.0 l/min. Projection 140 mm, depth adjustability 25 mm. Activated water hygiene flushing 24 hours after last activation, safety switch-off with continuous reflection and saving of statistical data. With option for parameterization and communication via optional, bidirectional remote control. Separate power supply via power supply unit 6.75 V / 12 V DC or AQUA 3000 open system accessories.

Spout projection

 (mm)

Item number

SAP#
2030038681
Product name
F5ET1013

Product properties

Type of mounting
In-wall installation with box
Type of operation
Sensor operation
Power supply connection
6,75 / 12 V DC / A3000 open
Article group
F5ET1014 ++
Diameter nominal
DN 15
Calculation flow rate cold water
0.07 liter per second
Calculation flow rate hot water
0.07 liter per second
Functional principle
Electronic self-closing
Minimum flow pressure
1.00 bar
Power consumption
1.50000
Volume flow rate at 3 bar
0.10 liter per second
Inlet size
G-3-4-B
Type of mixing
Thermostat
Material casing
Stainless steel
Material fitting
Brass
Sound insulation
No
Spout projection
140.00 mm
Surface finish casing
Satin finished
Surface finish fitting
Chromed
Type of tap
In-wall tap
Depressurised
No
Thermal disinfection
Prepared for automatic thermal disinfection
Protective shutdown
Yes
Volume flow rate bypass
0.05 liter per seconds
Default automatic hygiene flushing
24h after the last activity
Position of power connection
From top
Type of sensor
Opto-electronic sensor

Additional product information


Mandatory accessories

Optional accessories

Spare Parts

Show all related products

Related Products

F3E-Mix electronic in-wall mixer with battery operation
F3EM1011 ++

F3E-Mix electronic in-wall mixer with battery operation

Type of operation:
Sensor operation 
Type of mounting:
In-wall installation with box 
Type of sensor:
Opto-electronic sensor 
F5E-Therm electronic thermostat wall-mounted mixer for separate power supply
F5ET1005 ++

F5E-Therm electronic thermostat wall-mounted mixer for separate power supply

Type of operation:
Sensor operation 
Type of mounting:
Wall mounting 
Type of sensor:
Opto-electronic sensor 
F3E-Mix electronic pillar mixer with battery compartment
F3EM1001 ++

F3E-Mix electronic pillar mixer with battery compartment

Type of operation:
Sensor operation 
Type of mounting:
Tap hole 
Type of sensor:
Opto-electronic sensor 
F3E Electronic in-wall tap for separate power supply
F3EV1017 ++

F3E Electronic in-wall tap for separate power supply

Type of operation:
Sensor operation 
Type of mounting:
In-wall installation with box 
Type of sensor:
Opto-electronic sensor 
F3E electronic pillar tap with battery compartment
F3EV1001 ++

F3E electronic pillar tap with battery compartment

Type of operation:
Sensor operation 
Type of mounting:
Tap hole 
Type of sensor:
Opto-electronic sensor 
F3E Electronic in-wall tap for separate power supply
F3EV1017 ++

F3E Electronic in-wall tap for separate power supply

Type of operation:
Sensor operation 
Type of mounting:
In-wall installation with box 
Type of sensor:
Opto-electronic sensor 
F5E electronic pillar tap for separate power supply
F5EV1004 ++

F5E electronic pillar tap for separate power supply

Type of operation:
Sensor operation 
Type of mounting:
Tap hole 
Type of sensor:
Opto-electronic sensor 
F3E Electronic in-wall tap for separate power supply
F3EV1017 ++

F3E Electronic in-wall tap for separate power supply

Type of operation:
Sensor operation 
Type of mounting:
In-wall installation with box 
Type of sensor:
Opto-electronic sensor 
F3E-Mix Electronic in-wall mixer for separate power supply
F3EM1017 ++

F3E-Mix Electronic in-wall mixer for separate power supply

Type of operation:
Sensor operation 
Type of mounting:
In-wall installation with box 
Type of sensor:
Opto-electronic sensor 
F3E-Mix Electronic in-wall mixer for separate power supply
F3EM1017 ++

F3E-Mix Electronic in-wall mixer for separate power supply

Type of operation:
Sensor operation 
Type of mounting:
In-wall installation with box 
Type of sensor:
Opto-electronic sensor 
F5E-Therm electronic thermostatic wall-mounted mixer for separate power supply
F5ET1005 ++

F5E-Therm electronic thermostatic wall-mounted mixer for separate power supply

Type of operation:
Sensor operation 
Type of mounting:
Wall mounting 
Type of sensor:
Opto-electronic sensor 
F5E-Therm electronic thermostat wall-mounted mixer
F5ET1002 ++

F5E-Therm electronic thermostat wall-mounted mixer

Type of operation:
Sensor operation 
Type of mounting:
Wall mounting 
Type of sensor:
Opto-electronic sensor